Mine Rescue Pilot Study - Composite

Previous slide Next slide Back to first slide View graphic version


Notes:

This composite of all 10 CMR participants from March highlights the consistency of the results. 4 of the 10 (red ring) gained the same amount of core temperature, at a rate of about 1.8 º F per hour. A second group of 4 ( pink ring) gained about 1.1 º F per hr.

The ten individuals were a mix of ages, fitness levels and acclimatization to heat. The only significant difference between the two clusters is that the higher (red ring) group are all under 35 and everyone else is over 35.